Simulation of Carbon Dioxide Absorption Into Sodium Hydroxide Solution in a ‎Nutter-Valve Plate Column
Publication Type
Original research
Authors

The profiles of temperature, concentrations and hydrodynamic parameters along the column height were simulated for the absorption of carbon dioxide into a sodium hydroxide solution of total concentration up to 4.4 N in a Nutter-valve plate column. The influence of the CO2 concentration in the gas phase on the temperature and concentration profiles was estimated. The results of simulation were compared to an experiment for the case of low concentration of CO2 in the gas phase (~1%) and low concentration of Na OH solution (~1 N). Comparison of the Nutter-valve and sieve plate columns is also presented.

Journal
Title
Hung.J. Ind. Chem. 18., 67-79
Publisher
Hung.J. Ind. Chem. 18., 67-79
Publisher Country
Palestine
Publication Type
Both (Printed and Online)
Volume
18
Year
1990
Pages
67-79