The Influence of Holding Device Anchor Parameters On The Holding Force Magnitude, Of An Integrated Linear Electromagnetic Motor
Publication Type
Original research
Authors

This paper investigates the influence of the design parameters of the upper ferromagnetic shunt, namely the value of the holding areaHS,that creates a holding force HF, equal to that in breakaway stage in magnitude of this holding force at the breakaway stage. The design of an integrated circuit and the equivalent magnetic circuit of the integrated LEMM on breakaway stage was built, mathematical models of system were laid out. The most acceptable range of these ranges of magnitude of holding area is4.0...2.0HS, and this happens when4.0...2.0ush .The resulting holding force will vary in range of )15.0...05.0( to )55.0...2.0(.

Journal
Title
(AJEST), || Volume || 3 ||Issue|| 2|| Pages || 84-88||
Publisher
AJEST
Publisher Country
Pakistan
Publication Type
Both (Printed and Online)
Volume
3
Year
2013
Pages
84-88