Online sorting of recovered wood waste by automated XRF-technology. Part I: Detection of preservative-treated wood waste
نوع المنشور
بحث أصيل
المؤلفون
  • A. Rasem Hasan
  • John Schindler
  • Helena M. Solo-Gabriele
  • Timothy G. Townsendc
Waste wood is frequently contaminated with wood treatment preservatives including chromated copper arsenate (CCA) and alkaline copper quat (ACQ), both of which contain metals which contaminate recycled wood products. The objective of this research was to propose a design for online automated identification of As-based and Cu-based treated wood within the recovered wood waste stream utilizing an X-ray fluorescence (XRF) system, and to evaluate the detection parameters of such system. A full-scale detection unit was used for experimentation. Two main parameters (operational threshold (OT) and measurement time) were evaluated to optimize detection efficiencies. OTs of targeted metals, As and Cu, in wood were reduced to 0.02 and 0.05, respectively. The optimum minimum measurement time of 500 ms resulted in 98%, 91%, and 97% diversion of the As, Cu and Cr mass originally contained in wood, respectively. Comparisons with other detection methods show that XRF technology can potentially fulfill the need for cost-effective processing at large facilities (>30 tons per day) which require the removal of As-based preservatives from their wood waste stream.
المجلة
العنوان
Waste Management, 31, 688–694
الناشر
--
بلد الناشر
فلسطين
نوع المنشور
Both (Printed and Online)
المجلد
--
السنة
2011
الصفحات
--